Accuracy: ± 2% of the value read (regardless of the coupled converter).
MS3780
Sensor material: AISI316 stainless steel
Nominal pressure: from PN 16 to PN 64
Process connections: Threaded or flanged
Liquid temperature: from -20 to + 100 ° C (130 ° for separate version)
Coating material: PEEK
Electrode material: Hastelloy C276
Accuracy: ± 2% of the value read (regardless of the coupled converter).
Electromagnetic flowmeter transmitter
MV210
Accuracy: ± 0.2% of the value read with speed from 0.5 m/s
Repeatability: ± 0.1%
Available outputs: up to 2 digital outputs, up to 2 analog outputs, one of which Hart, Modbus communication
Flexible mounting to view the display on the other
Housing material: Nylon loaded with 15% glass fiber or Aluminum or AISI304
Protection IP 67 (on request IP68)
Available functions: low flow cutting, bidirectional measurement, peak cutting, empty pipe, alarm limit etc.
MV110
Accuracy: ± 0.8% of the read value (± 0.4% of the optional read value).
Repeatability: ± 0.2% Available outputs: 3 digital, max 2 analog, one of which Hart, Modbus communication.
Flexible mounting to view the display on the other.
Housing material: Nylon loaded with 15% fiberglass or Aluminum.
Protection IP 67 (on request IP68)
MV800
Housing in die-cast aluminum or in AISI304 (cover in PA6 if with display, degree of protection IP 67.
Power supply 10-30 V DC. Electrical connections via 5-pole connector.
PC programming via dedicated MCP software.
Temperature sensor
PLT
Resistance thermometer PT500 (PT100 and PT1000 on request).
Suitable for use in the calculation of the thermal energy paired calibrated.
Sensors according to EN1434 – 2
The PLT are produced with suitable rod to the DN of the line on which to install them.
Accuracy conforms to EN 60751 + A2: 2000, and subject to the Directives 2004/22/EC of 31 March 2004: – Annex I/Annex MI-004 for heat meter.
The sensors coupled can also be supplied individually.
Versions up to 10 meters with cable or head-to-wire longer.
Wells with seal/sealing on request.
PLH
PT500 or PT100 and PT1000 thermoresistances on request).
Suitable for use for the calculation of thermal energy calibrated in pairs.
Sensors compliant with EN1434 – 2
The PLHs are produced for installation by means of a thermowell.
Accuracy compliant with EN 60751 + A2: 2000, and subject to directives 2004/22 / EC of March 31, 2004 – Annex I / Annex MI-004 for calorie counters.
Paired sensors can also be supplied individually.
Versions up to 10 meters with cable or with wiring head.
Ball valve (Ball-Valve) Wells with seal / plumbing included.
BTU meters
MV311
MID approved for water and water/glycol
QUICK SETUP function
Four pulse inputs
Analogic or digital Input for thermal vector fluid
Stand-alone configuration through USB cable
Compact ultrasonic
IFX-M4-E3
Measuring range from 0,6m3/h to 60m3/h
Size from ¾” to DN100
Nominal pressure PN16 o PN25
Execution T90 o T130
Function ONE
Three protocols simultaneously
Clamp on ultrasonic
IFX-F100
Ultrasonic measurement principle based on transit time
Speed range 0.01 – 25 m/s
Resolution 0.25 mm/s
Repeatability 0.15% of the measured value
Accuracy (Flow / Volume) ± 1-3% of the measured value depending on the application ± 0.5% of the measured value with a calibration in the field for comparison with the master meter
Accuracy (speed) ± 0.5% of the measured value
Measurement frequency 1 Hz
Response time 1 second
Damping reading 0… 99 seconds
Solid or gas content in the fluid <10% by volume
Aluminum housing for wall mounting
Degree of protection IP66 (EN60529)
Ambient temperature –10 +60 ° C (for electronics)
Power supply 100… 240 V a.c. or 9 … 36 V DC
Consumption <5 W
Backlit graphic LCD display
Weight (approx.) 0.75 kg
Menu languages Italian, English, Spanish (others on request)
IFX-P200
Speed range 0.01 – 25 m/s
Resolution 0.25 mm/s
Repeatability 0.15% of the measured value
Accuracy (Flow / Volume) ± 1-3% of the measured value depending on the application ± 0.5% of the measured value with a calibration in the field for comparison with the master meter
Accuracy (Speed) ± 0.5% of the measured value
Measurement frequency 1 Hz
Response time 1 second
Damping reading 0 … 99 seconds (selectable)
Solid or gas content in the fluid <10% by volume
Case Robust ABS case with shockproof rubber shell IP65 protection degree (EN60529)
Ambient temperature –10 +60 ° C (for electronics)
Power supply via internal rechargeable batteries with operating autonomy up to 24 hours with 100% charged batteries
Backlit graphic LCD display
Weight (Approximate) 0.65 kg (instrument only) 7 kg (transport case with instrument and pair of sensors